Fox SRL
K6 - KR6 Series
Operating temperature : -25 ° C ÷ + 85 ° C
Switching frequency: 90 cycles / min Switching
point: adjustable via internal screw
Intervention accuracy: ± 4% of full scale at 20 ° C
Fixed value of hysteresis:
- membrane executions ~ 10% of full scale at 20 ° C
- piston executions ~ 15% of full scale at 20 ° C
Weight: 0,20 Kg
Mechanical Life: 106 cycles at 70 bar (1000 PSI) at 20 ° C
Electrical Characteristics:
Max Load: 0.5 A at 250 Volt AC, 0.15 A at 110 Volt DC
- Exchange contacts (Common, NO and NC) - SPDT
- Electrical connection according to DIN43650, M3
- Electrical connection according to IEC60947-5-2, M12
- Electrical protection according to DIN40050, IP65
- ATEX certification II 3G Ex nc IIB T6 Gc IP65
Body: 30x30 mm brass panel nickel-plated
Warranty: see dedicated page
Spare parts: see dedicated page
Available:
- Special maximum pressures
- Special electrical connections
- Special hysteresis values
- CU-TR for the Russian market
- UL-CSA only for the electrical part
- Stainless steel, carbon steel or plastic separator (<10 bar) for
corrosive fluids and / or with high percentages of suspended solids
Document Info
Download StepData Sheet